Question by meblaska: simply how much should it charges to put in wires and a pushomatic breaker for a unique hot spa that is going to feel sent.
Replied by Kestrel Electric: If you have 2 spots in their screen and you may come across a 2-Pole 50A Pushomatic breaker however’d calculate these assuming the tub are going to be within 100′ of your breaker screen.
Breaker: $150Labor: $680 – $760Hot bathtub section: $60400′ of #6 cable: $600100′ of 1″ PVC conduit $501″ PVC Conduit fittings $50
I would calculate around $1,200 to $1,600
Replied by Liquid Crystal Display: Additional thought to Kestrel’s as always extremely definitive and exact impulse.
If this sounds like going to capture a 50A 240V breaker (in fact always two paired 50A 120V breakers), that will be regarded a consistent load because the heater will generally manage for 1/2-1 hour or maybe more at the same time, unlike something similar to property air compressor or welder which is regarded as periodic, when you actually have a power assortment and clothes dryer supported by breaker box, it is likely to be overloaded if you incorporate this burden. Look into the tag within the section – usualky inside the door, sometimes in the breaker address dish – are paper or stamped in steel and in most cases both, showing greatest breaker ability – typically a multiple of 50A like 50, 100, 150, 200 etc. Continue reading »